Test ID: Complement C3a

Test Codes


  • Exsera Order Code: C3AQ
  • CPT Code: 86160
  • EPIC Code: LAB3073

Specimen Requirements


Specimen Type: EDTA Plasma

Collection Tube: Lavender top, K2 or K3 EDTA

Collection Instructions:  Store samples on wet ice and centrifuge within 2 hours of draw. Then transfer to cryogenic tubes and aliquot as necessary before storing tubes in the appropriate freezer.

Volume Required: ~200 mcL  

Storage/Transport Temperature: Frozen @ -80C

Stability: 855 Days while stored @ -80C from date of draw

Unacceptable Conditions: Samples stored at >-80C, previously thawed samples, or unlabeled samples. 

Ordering Recommendation


Reference Interval


Normal Human: 22 - 423 ng/mL

ULOQ/ALQ: N/A

LLOQ/BLQ: N/A

Test ClassifICATION


This test has been cleared by the US Food and Drug Administration and is used per manufacturer's instructions and per Exsera's SOPs. Performance characteristics were verified by Exsera in a manner consistent with CAP/CLIA requirements.

Methodology


ELISA or EIA

Patient Testing Turnaround time


  • Standard: 7-14 Days
  • Expedited: 4-5 Days

Aliases


C3a, C3 fragment C3a, C3a anaphylatoxin, C3a Complement Level

Additional Notes


Diagnostic samples held for ~2 months before disposal of remaining sample